HardieSmart® Aged Care Wall System
Built for the Compliance Demands of Class 9c
Aged care and residential care facilities carry some of the most demanding fire and acoustic performance requirements in the NCC, a reflection of the reduced mobility and higher vulnerability of the people who live in them. Getting the wall system specification right in a Class 9c building isn’t a nice-to-have; it’s central to the building’s ability to be certified and occupied at all.
12%
More compact than standard plasterboard system, similar performance
90mm
Timber frame configuration
9c
Purpose-built for Class 9c aged care and healthcare buildings
Technical Specifications
Fire Resistance Level
Suitable building class
Frame configuration
Insulation
Internal lining
Acoustic testing
Compactness advantage
Services allowance
Assessment
Bracing capacity
Applications
Why Aged Care Needs Its Own System
The Floor Area Case for Aged Care Developments
Compounds across every wall in the facility
A 12% thickness reduction on a single wall is a modest number. Multiplied across every resident room separating wall and corridor wall in a facility with dozens or hundreds of beds, that recovered floor area becomes a genuinely significant yield improvement, either as additional saleable or leasable area or as more generous circulation and amenity space within the same building footprint.
Compliance-ready documentation for a demanding approval process
Aged care facility approvals typically involve rigorous scrutiny from certifiers, fire engineers and health department reviewers. Having a system that was specifically engineered and documented for Class 9c, rather than adapted from a Class 2 system, simplifies that review process and reduces the risk of a compliance gap being identified late in design or during construction.
Durability suited to institutional operating conditions
Aged care facilities operate under demanding maintenance and cleaning regimes over long operational lifespans. The James Hardie™ fibre cement cladding compatible with the Aged Care system is engineered for harsh conditions, including coastal environments; resists swelling and warping; and holds paint well over repeated cleaning cycles, relevant considerations for a building type with an extended, intensive service life.
Termite and moisture resistance
Aged care facilities are long-life institutional assets, often operated for decades. Termite resistance and dimensional stability under moisture exposure reduce the long-term maintenance liability for facility operators, compared to systems that are more vulnerable to these forms of deterioration over an extended service life.