Fire Separation in the Tightest Spaces on Site

Cantilevered balconies, projecting wall elements and the narrow gaps between attached dwellings at ground level all share the same design constraint: there’s very little room for a fire-rated wall assembly, but the fire separation requirement doesn’t go away just because the space is tight. Conventional twin-frame or masonry separating walls simply don’t fit in these locations without eating into usable space that the design can’t spare.

The HardieSmart® Blade Wall System is built for exactly this problem. A single-layer wall system, no cavity, no twin frame, starting from just 102 mm thick, delivering a Fire Resistance Level of up to one hour in a genuinely compact profile. Its single-layer design means no fire lining is required between tenancy frames, which removes a specific weather-exposure risk: fire linings sandwiched between frames in exposed locations like cantilevered balconies are vulnerable to moisture ingress and mould growth if the outer layer is ever compromised. The Blade Wall System sidesteps that risk entirely by not requiring the sandwich in the first place.

102mm

Minimum wall thickness

1 hour

Fire Resistance Level achievable

Single

Layer design: no fire lining sandwiched between frames

Request a quote

Technical Specifications

Design guide

Fire Resistance Level

Up to 1 hour (FRL) — for timber-framed external separating walls

Suitable building class

Class 1 and Class 10a timber-framed buildings

Minimum wall thickness

102mm

Construction

Single-layer design — no fire lining required between tenancy frames

Compatible cladding

Most James Hardie™ external claddings may be used

Performance attributes

Fire-resistant · Acoustic · Thermal · Structural bracing

Compatibility

Compatible with other frequently used common wall systems

Primary applications

Cantilevered balcony separating walls · ground wall extensions · projecting fire-rated elements

Comparative benchmark

Compared to standard plasterboard systems with a 90mm timber frame and similar acoustic/fire performance

Where the Blade Wall System Belongs

Blade Wall is purpose-designed for external projections and separating conditions where wall thickness is the binding constraint, situations that the other HardieSmart® systems, designed primarily for full-height ground-to-roof separating walls, aren’t optimised to solve.

Cantilevered balconies

Where two adjoining dwellings each have a cantilevered balcony and the separating wall between them needs to achieve fire resistance in a genuinely thin, lightweight, single-layer profile, exactly the condition Blade Wall was engineered for. Its single-layer design and exposure-tolerant construction suit this specific application better than a twin-frame system designed for full-height separating walls.

Ground wall extensions and projecting elements

Fin walls, privacy screens between adjoining ground-floor outdoor spaces and other projecting architectural elements that need fire separation without the bulk of a conventional wall. Blade Wall’s compact profile keeps these elements visually light while still satisfying the fire compliance requirement.

Tight urban and narrow sites

On sites where every centimetre of separation between dwellings has been fought for at the design stage, Blade Wall’s starting thickness of 102mm recovers space that a bulkier system would consume, directly relevant on narrow-lot infill and high-density attached housing.

Locations with weather exposure risk

Because Blade Wall doesn’t require a fire lining sandwiched between two frames, it avoids the specific failure mode where moisture gets trapped between layers in an exposed location, like a cantilevered balcony soffit, and causes mould growth or lining deterioration that isn’t visible until it’s a real problem.

Featured Projects with HardieSmart® Blade Wall System

Frequently Asked Questions

Why doesn't the Blade Wall System need a fire lining between frames?
The Blade Wall System uses a single-layer design rather than the twin-frame-with-cavity approach used in systems like Intertenancy. Because there’s no cavity sandwiched between two separate frames, there’s no fire lining trapped in a space where moisture could accumulate undetected. This is a specific advantage in exposed applications like cantilevered balconies, where a sandwiched fire lining would be vulnerable to weather-driven moisture ingress and potential mould growth if the outer cladding layer were ever compromised.
The HardieSmart® Blade Wall System starts as low as 102 mm thick, the same minimum thickness as the Boundary Wall System, though the two systems are engineered for different applications. Blade Wall is designed for external projections, including cantilevered balconies and tight urban sites; Boundary Wall is designed for full-height external walls at or near the property boundary.
Most James Hardie™ external claddings can be used with the Blade Wall System, giving architects and builders design flexibility in matching the Blade Wall element to the broader facade material palette. Confirm the specific cladding compatibility and any minimum thickness requirements against the current HardieSmart® Blade Wall System Design Guide.
Blade Wall is specifically engineered for external projections and separating conditions like cantilevered balconies and ground wall extensions, not as a general-purpose alternative to the Intertenancy Wall System for full-height separating walls between attached dwellings. For a full-height common wall between two sole occupancy units, the Intertenancy Wall System is the appropriate HardieSmart® product. Contact our team to confirm the right system for your specific wall condition.